IO Modules
Showing 1–30 of 55 results
- IO Modules, Phoenix Contact
Inline ME terminal – IB IL 24 DO 4-ME – 2863931
Inline, Digital output terminal, Digital outputs:Â 4, 24 VÂ DC, 500 mA, connection method:Â 3-wire, transmission speed in the local bus:Â 500 kbps, degree of protection:Â IP20, including Inline connector and labeling field
SKU: 2863931 - IO Modules, iSMA Controlli
iSMA – MINI Series
Key Features
- 14 different types
- Small dimension
- Manual override switches
- Built-in light, cooling and heating control modes
- Present sensor support modes
- All Digital Inputs work as fast counters up to 100 Hz
- Universal Inputs have 16-bit resolution which increases the accuracy of measurement
- Wide range of supported temperature sensors in
- Celsius and Fahrenheit degrees (NTC, PT1000 etc.)
- Automatic detection of the signal type in the case of Universal Inputs
- Digital Outputs 230 V AC max. 3 A or 8 A allow for direct control without additional relays
- Triac Outputs: 0,5 A @ 24 V AC, 0,5 A @ 230 V AC
- Analog Output with max. 20 mA load per channel allow direct control of relays (12 V DC) or SSR with PWM support
- LEDs indicate the status of inputs and outputs
- Supports open standards: BACnet or Modbus
- Built-in Modbus Gateway TCP/IP to RS485
- 1 x Fast Ethernet
- Simple and fast addressing from 1 to 99
For PDFs, please see the Specification tab below
SKU: n/a - BMS Controllers, IO Modules, iSMA Controlli
iSMA – RAC18-IP Room Application Controller
The RAC18-IP is a multifunctional device providing comfort in a single room or a zone in the building. 18 onboard I/O’s with Ethernet and serial port make the controller a versatile system for comfort management, light and blind control, and integration and monitoring. The RAC18-IP controller has a built-in nano EDGE ENGINE – the cutting-edge software that allows for constructing multiple applications and provides a set of libraries and components tailored to create cycle-driven user applications. This solution provides an automatic BACnet exposure and real-time programming.
Maintenance and programming of the device are possible from anywhere in real time with a dedicated, free-of-charge tool.
The RAC18-IP ensures an easy replacement process with a system and applications on a removable SD card.SKU: RAC18-IP - IO Modules, Phoenix Contact
Bus coupler – IL ETH BK DI8 DO4 2TX-PAC – 2703981
Inline, Bus coupler, Modbus/TCP(UDP), RJ45 socket, Digital inputs: 8, 24 VÂ DC, connection method: 3-wire, Digital outputs:Â 4, 24 VÂ DC, 500 mA, connection method:Â 3-wire, transmission speed in the local bus:Â 500 kbps / 2 Mbps, degree of protection:Â IP20, including Inline connectors and marking fields
SKU: 2703981 - IO Modules, iSMA Controlli
iSMA – MIX Series
The product group of I/O modules of the MIX series has been designed for building distributed control systems using JACE or AAC20 devices.
All the MIX Series modules have been equipped with the most commonly used types of I/O in building automation (MIX of all types of I/O in one unit).The modules are factory-equipped with the two most popular open communication protocols: Modbus (ASCII, RTU, TCP/IP) and BACnet MS/TP, IP), which are selected using DIP switches. There are two versions of the modules: modules with RS485 interface and with 2x Ethernet and RS485 interfaces.
Devices with 2x Ethernet and RS485 interfaces have the added functionality of “Modbus Gateway TCP/IP to Modbus ASCII/RTU”, enabling for the connection of additional modules/devices that communicate via Modbus RS485. The Modbus Gateway functionality is active also for devices
configured as BACnet IP modules. IP modules, communicating either in Modbus or BACnet, are always master units on the network. One major advantage of supporting the modules with open communication standards is the versatility to install them in both new and completed installations, as part of an existing BMS.Addressing the modules takes place via rotary switches, which facilitates and accelerates the process of commissioning the system. Built-in mini USB allows for initial configuration of the unit without power supply.
SKU: n/a - IO Modules, Phoenix Contact
Inline terminal – IB IL AI 8/SF-PAC – 2861412
Inline, Analog input terminal, Analog inputs: 8, 0 V … 5 V, -5 V … 5 V, 0 V … 10 V, -10 V … 10 V, 0 V … 25 V, -25 V … 25 V, 0 V … 50 V, 0 mA … 20 mA, 4 mA … 20 mA, -20 mA … 20 mA, 0 mA … 40 mA, -40 mA … 40 mA, connection method: 2-wire, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connectors and marking fields
SKU: 2861412 - IO Modules, Tridium
Tridium IO-R-34 Remotely Connected I/O module
- 16 Universal inputs: Type 3 (10k) thermistors, 0-100K ohm, 0-10VDC, 0-20 mA with external resistor
- 10 Relay outputs (Form A contacts, 24VAC @ .5 amp rated)
- 8 Analog outputs (0-10VDC)
- Includes on-board 24V ac/dc input power supply
SKU: IO-R-34 - IO Modules, Phoenix Contact
Inline terminal – IB IL 24 DI 32/HD-PAC – 2862835
Inline, Digital input terminal, Digital inputs: 32, 24 VÂ DC, connection method: 1-wire, transmission speed in the local bus:Â 500 kbps, degree of protection:Â IP20, including Inline connectors and marking fields
SKU: 2862835 - IO Modules, iSMA Controlli
iSMA-B-CVT-RS485
Protection in the event of short-circuit of
the signal cable with the screen
• Support for stopping and resuming work
• Resistor terminating the RS485 line: 120
ohms, switched via a switch
• Ability to save user parameters in nonvolatile EEPROM memory
• LEDs indicating the sending and receiving
of data
• Female B-type USB connector
• Serial UART transmission: 7 or 8 data bits,
1 or 2 stop bits, parity check (none, parity,
odd parity, sign, space)SKU: iSMA-B-CVT-RS485 - IO Modules, iSMA Controlli
iSMA-B-MG-IP
• M-Bus TCP/IP and UDP/IP to M-Bus gateway
• Modbus TCP/IP to Modbus RTU/ASCII gateway
• Up to 180 meters (devices) of various types
• Two independent gateways operating
simultaneously in one device
• Built-in power supply for up to 60 M-Bus meters
(devices)
• Direct connection for up to 6 M-bus branches
• Built-in Mini USB port for configuration and
firmware updatesSKU: iSMA-B-MG-IP - IO Modules, Phoenix Contact
Bus coupler – IL MOD BK DI8 DO4-PAC – 2878696
Inline, Bus coupler, Modbus/RTU, D-SUB-9 female connector, Digital inputs: 8, 24 VÂ DC, connection method: 3-wire, Digital outputs:Â 4, 24 VÂ DC, 500 mA, connection method:Â 3-wire, transmission speed in the local bus:Â 500 kbps / 2 Mbps, degree of protection:Â IP20, including Inline connectors and marking fieldsSKU: 2878696 - IO Modules, Phoenix Contact
Inline function terminal – IB IL DI 8/S0-PAC – 2897020
Inline, Digital input terminal, Digital inputs: 8 (S0 counter inputs), 24 VÂ DC, connection method: 4-wire, transmission speed in the local bus:Â 500 kbps, degree of protection:Â IP20, including Inline connectors and marking fields
SKU: 2897020 - IO Modules, Phoenix Contact
Inline function terminal – IB IL DALI/MM-PAC – 2700605
Inline, DALI master, Multi-master-capable, integrated DALI power supply unit, safe electrical isolation, transmission speed in the local bus:Â 500 kbps, degree of protection:Â IP20, including Inline connectors and marking fields
SKU: 2700605 - IO Modules, Phoenix Contact
Inline terminal – IB IL AO 4/8/U/BP-PAC – 2878036
Inline, Analog output terminal, Analog outputs: 8, 0 V … 10 V, -10 V … 10 V, 0 V … 5 V, -5 V … 5 V, connection method: 2-wire, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connectors and marking fields
SKU: 2878036 - IO Modules, Phoenix Contact
Inline ME terminal – IB IL AO 2/U/BP-ME – 2863957
Inline, Analog output terminal, Analog outputs: 2, 0 V … 10 V, -10 V … 10 V, connection method: 2-wire, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field
SKU: 2863957 - IO Modules, Phoenix Contact
Inline ME terminal – IB IL AI 2/SF-ME – 2863944
Inline, Analog input terminal, Analog inputs: 2, 0 V … 10 V, -10 V … 10 V, 0 mA … 20 mA, 4 mA … 20 mA, -20 mA … 20 mA, connection method: 2-wire, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field
SKU: 2863944 - IO Modules, Phoenix Contact
Inline terminal – IB IL DO 4 AC-1A-PAC – 2861658
Inline, Digital output terminal, Digital outputs:Â 4, 230 V AC, 1 A, connection method:Â 3-wire, transmission speed in the local bus:Â 500 kbps, degree of protection:Â IP20, including Inline connectors and marking fields
SKU: 2861658 - IO Modules, Phoenix Contact
Inline terminal – IB IL DO 1 AC-PAC – 2861920
Inline, Digital output terminal, Digital outputs:Â 1, 230 V AC, 500 mA, connection method:Â 3-wire, transmission speed in the local bus:Â 500 kbps, degree of protection:Â IP20, including Inline connector and labeling field
SKU: 2861920